Client: Domestic
Our client, a homeowner in Newport, tasked Timberwise with inspecting the physical construction of the basement in order to provide a design and quotation for a waterproofing system to protect the basement from water ingress. We provided the client with a detailed plan and constructed a Grade 1A waterproofed solution which adhered to BS 8102:2022 guidelines, protecting the basement from ground water ingress and hydrostatic pressure. The weather conditions were not recorded for this project.
Challenges
With any basement waterproofing task, there are a number of potential risks to factor in when it comes to the design. There is always a risk of water ingress caused by changing water tables, which occurs when underground water rises or falls. Other risks include the potential for localised flooding, blocked drains, or heavy rainfall which can cause localised ground saturation which threatens to seep into the basement area.
For this specific project, we had identified the wall to floor junction as the weakest point when it came to potential water ingress. We also needed to manage water ingress effectively without placing any additional hydrostatic loads on the existing structure.
We also required the client to clear all stored items, disconnect the electrical wall points, and supply dedicated RCD-protected electrical feeds prior to the membrane’s installation.
Perimeter drainage channels we needed to construct would also need careful positioning to avoid dry-lining systems, whilst still being accessible to maintenance jetting ports. We also ran a risk of water ingress during power cuts if the pumping station, which channels water away from the property, if it didn’t have a battery backup.
Observations
Our survey found a below-ground domestic basement that required full waterproofing protection to meet Grade 1a habitable standard requirements. The then-current floor slab needed to be excavated for the construction of a sump chamber and a preformed perimeter rebate for drainage channels.
Solutions
Prior to our work commencing, the client was to remove all of their stored items from the basement. They also were required to remove all electrical cables and points from the target walls to allow us to carry out our work safely. The client was to also secure an external contractor to install two independent electrical feeds from the consumer unit, each protected by a separate RCD, for the pumps, high-level alarm, and battery backup. These measures enabled us to begin the work by excavating a 600mm x 600mm x 600mm floor aperture for the sump chamber and form a perimeter rebate in the floor slab.
For the waterproofing solution itself, we designed and installed a BS 8102:2022 compliant Type C cavity drained waterproofing system. We achieved this by installing an 8mm high-density extruded cavity drainage wall membrane with stud formation, fixed using dual-purpose sealed plugs in a curtain-hung configuration. For the floor, we installed a cavity drain membrane for it, sealed at any overlapping joints and around the perimeter where it connected to the wall membrane.
While the membrane “catches” and traps water behind a surface to prevent it leaking into an area, it still needs to be safely channelled away from the construction. We created a perimeter drainage channel within the floor slab rebate at all the wall to floor junctions. This would allow for any water ingress to be re-routed directly to a sump chamber where it can be pumped away from the house.
We strategically installed jetting and rodding eyes along the channel to allow for ongoing system inspection and any subsequent cleaning. We then installed a 600mm x 600mm x 600mm groundwater sump chamber which was concreted into the floor aperture.
We then had to connect the discharge pipe to an external surface water drainage gully, to ensure any accumulated water was appropriately diverted away from the basement. We installed a dual-pump station, which also included a water alarm system that would notify the client if high levels of water were detected, to mitigate the risk of overflowing water. We included the recommendation and specification of a backup unit for the pump system to the client to ensure it stayed operational during mains power failures.
To finish the area off and make it suitable for its intended purpose, we installed a chipboard floating floor which was laid over the cavity drain floor membrane. The wall membranes were fixed to allow the client to choose their preferred dry-lining, with options such as timber battens, dot and dab plasterboard, or an independent stud partition. We then arranged a final inspection with the client prior to them applying any final wall and floor finishes to ensure they did not hinder the membrane. We also performed a flood test prior to any finishing works to ensure water was flowing into the channels and the sump chamber without it pooling.
Results
The results were that we provided the client with a comprehensive survey and achieved a BS 8102:2022 Grade 1a Type C waterproofing design that was suitable for habitation and storage. The solution was able to deliver a controlled groundwater drainage system, through the use of pressure-equalizing cavity membranes, perimeter channels, and automated pumping. The structural integrity of the basement was also preserved, as the solution was applied without causing hydrostatic load to the external masonry.
Our solution offered the client with a long-term guarantee, with a 10-year assurance for the cavity drain membrane, alongside options for an insurance-backed guarantee (GPI) and annual servicing.